Equipment
Equipment is purchased and maintained by project Inframat
Fourier Transform Infrared (FTIR) spectrometer Bruker Invenio R with resolution better than 1 cm -1.
The equipment has the following accessories:
• MIRacle ZnSe reflection ATR plate with a spectral range of 4000 – 500 cm- см-1;
• Pike tech reflection ATR plate with a spectral range of 4000 – 80 cm- см-1;
• Al/KRS-5 wire-grid type polarizer
The Laboratory of Instrumental Chromatography and Mass Spectrometry is equipped with the following equipment:
• Gas chromatograph Hewlett Packard 6890 GC System Plus/5973 MSD coupled to a mass selective detector with a single quadrupole, with an installed mass spectral library for identification (NIST05, Agilent Essential Oils library) and access to free Internet resources (the "Terpenoid" libraries, etc.);
• Agilent 7820A GC System Plus/5977 B gas chromatograph, coupled with a mass selective detector and a flame ionization detector (donated by the Swiss National Science Foundation). The instrument is equipped with a system for precise separation of the gas flow after the analytical column (post-column splitter), which allows for simultaneous analysis of both detectors, providing the possibility of both identification and quantitative analysis in a single analysis. The instrument is equipped with an automatic sampler HT2800T, with the ability to operate in three different modes – liquid sample introduction, static head-space analysis (HS) and solid-phase microextraction (SPME). A wide range of capillary GC columns with a variety of stationary phases, including chiral phases suitable for enantioselective gas chromatography (ES-GC), are available. Instrument control and data acquisition are performed by Mass Hunter Workstation software. NIST 14 mass spectral libraries, Wiley 7th Mass spectra register and FFNSC3 Flavor and Fragrance GC/MS library are available.
• Agilent 1100 series high-performance liquid chromatograph equipped with a UV-Vis diode array detector (DAD) and an Evaporative Light Scattering Detector (ELSD)
Оборудването е закупено и се поддържа по проект:

The NMR Centre is equipped with two modern NMR spectrometers:
Bruker Avance II+ 600 with available probeheads:
• 5 mm direct dual probehead (BBO, 31P - 109Ag/1H), with actively shielded Z-gradients and automatic tuning and matching accessory (ATMA) ;
• 5 inverse triple probehead (TBI, 1H/31P - 109Ag/13C) with actively shielded Z-gradients;
• 5 mm MIC-Diff30 diffusion dual probehead (1H/31P);
• 4 mm CP/MAS dual probehead (31P - 15N/1H) for solid state;
• 4 mm HRMAS dual probehead (1H/13C) for sample at liquid-solid state limit.
Bruker DRX 250 probeheads:
• 5 mm direct dual probehead (BBO, 31Р - 109Ag / 1H);
• 5 mm quattro probehead (QNP, 1Н, 13С, 31Р, 19F) with actively shielded Z-gradients.